Instrumentation cable, reinforced outer sheath, meter marking

Logo Image
Produktfoto
Technical data
  • Special core insulation of PE
  • Conductor resistance
    0,5 mm²  max. 39,2 Ohm/km
    0,75 mm²  max. 24,6 Ohm/km
    1,3 mm²  max. 14,2 Ohm/km
  • Temperature range
    flexing -5°C  to  +50°C
    fixed installation -40°C  to  +70°C
  • Operating peak voltage max. 300 V
    (not for heavy current installation purposes)
  • Test voltage
    core/core  2000 V
    core/screen  1000 V
  • Mutual capacitance  at 800 Hz
    core/core  0.5 mm²  60 pF/m
    for 1 and 2 pairs  75 pF/m
    core/core  0.75 mm²  65 pF/m
    for 1 and 2 pairs  110 pF/m
    core/core  1.3 mm²  75 pF/m
    for 1 and 2 pairs  100 pF/m
  • Inductance
    max. 0,75 mH/km
  • Cross-talk attenuation
    at 60 kHz  min. 0,88 dB/km
  • Minimum bending radius
    7,5x outer Ø
Cable structure
  • Bare copper conductor, multi wire
  • Conductor construction:
    0,5 mm² = 7x0,3 mm
    0,75 mm² = 7x0,37 mm
    1,3 mm² = 7x0,49 mm
  • Core insulation of PE
  • Cores coloured
    with number print 1/1, 2/2 etc.
    pair: a-core = BK; b-core = WH
    triple: a-core = BK; b-core = WH;
    c-core = RD
  • Cores twisted to pairs with optimum pitch
  • Pairs stranded in layer
  • 1 communication core 0,5 mm², PE-insulated,
    orange (for multicore version)
  • Foil wrapping
  • Electrostatic screen (St) of plastics-coated
    metal foil
  • Tinned drain-wire, 0,5 mm² = 7x0,3 mm
  • Outer sheath of PVC, reinforced,
    black (RAL 9005) or blue (RAL 5015)
  • With meter marking
  • Wall-thickness acc. to
    DIN VDE 0816-1, table 7, col. 1
Note
  • Coppper weight including communication
    core and drain-wire.
  • With blue outer sheath for hazardous areas
    to hazard type -i- for intrinsically safe
    installation acc. to DIN EN 60079-14
    section 12.2.2 (VDE 0165-1)
  • The conductor is metrically constructed
    (mm²).  The AWG designation is
    approximate and purely informative.
Application
Instrumentation cables are used in data processing and process control. Instrumentation cables are suitable for fixed installations in damp locations, in open spaces and for underground laying.
CE = Product conforms with Low-Voltage Directive 2014/35/EU.
Downloads
Data sheet
Certificate of compliance

Part no.

No.pairs x
cross-sec.
mm²

Sheath
colour

Outer Ø

approx. mm

Cop.
weight

kg / km

Weight

approx. kg / km

AWG-No.

20099

1 x 2 x 0,5

black

7,5

15,0

74,0

20

20100

2 x 2 x 0,5

black

9,8

30,0

117,0

20

20101

4 x 2 x 0,5

black

11,3

50,0

140,0

20

20233

6 x 2 x 0,5

black

13,1

70,0

190,0

20

20102

8 x 2 x 0,5

black

14,6

90,0

215,0

20

20103

10 x 2 x 0,5

black

16,1

110,0

220,0

20

20104

12 x 2 x 0,5

black

16,4

130,0

280,0

20

20105

16 x 2 x 0,5

black

18,3

170,0

352,0

20

20106

20 x 2 x 0,5

black

19,2

210,0

385,0

20

20107

24 x 2 x 0,5

black

22,3

250,0

468,0

20

20108

36 x 2 x 0,5

black

24,5

370,0

656,0

20

20109

48 x 2 x 0,5

black

27,7

490,0

854,0

20

20149

1 x 2 x 0,75

black

7,9

20,0

74,0

19

20150

2 x 2 x 0,75

black

10,4

35,0

123,0

19

20151

4 x 2 x 0,75

black

11,9

65,0

164,0

19

20152

8 x 2 x 0,75

black

15,0

125,0

258,0

19

20153

10 x 2 x 0,75

black

17,0

154,0

305,0

19

20154

12 x 2 x 0,75

black

17,6

185,0

350,0

19

20155

16 x 2 x 0,75

black

19,5

245,0

445,0

19

20156

20 x 2 x 0,75

black

21,5

298,0

520,0

19

20157

24 x 2 x 0,75

black

24,0

365,0

620,0

19

20158

36 x 2 x 0,75

black

26,5

532,0

940,0

19

20159

48 x 2 x 0,75

black

30,3

708,0

1250,0

19

20125

1 x 2 x 1,3

black

8,7

31,0

102,0

-

20132

1 x 3 x 1,3

black

9,0

44,0

116,0

-

20126

2 x 2 x 1,3

black

11,5

62,0

161,0

-

20127

4 x 2 x 1,3

black

14,3

114,0

230,0

-

20234

6 x 2 x 1,3

black

16,0

168,0

310,0

-

20128

8 x 2 x 1,3

black

17,3

218,0

377,0

-

20129

12 x 2 x 1,3

black

20,5

322,0

515,0

-

20130

16 x 2 x 1,3

black

23,0

426,0

656,0

-

20131

24 x 2 x 1,3

black

27,9

684,0

952,0

-

20235

1 x 2 x 0,5

blue

7,5

15,0

74,0

20

20236

2 x 2 x 0,5

blue

9,8

30,0

117,0

20

20237

4 x 2 x 0,5

blue

11,3

50,0

140,0

20

20238

6 x 2 x 0,5

blue

13,1

70,0

190,0

20

20239

8 x 2 x 0,5

blue

14,6

90,0

215,0

20

20240

10 x 2 x 0,5

blue

16,1

110,0

220,0

20

20241

12 x 2 x 0,5

blue

16,4

130,0

280,0

20

20242

16 x 2 x 0,5

blue

18,3

170,0

352,0

20

20243

20 x 2 x 0,5

blue

19,2

210,0

385,0

20

20244

24 x 2 x 0,5

blue

22,3

250,0

468,0

20

20245

36 x 2 x 0,5

blue

24,5

370,0

656,0

20

20246

48 x 2 x 0,5

blue

27,7

490,0

854,0

20

20169

1 x 2 x 0,75

blue

7,9

20,0

74,0

19

20170

2 x 2 x 0,75

blue

10,4

35,0

123,0

19

20171

4 x 2 x 0,75

blue

11,9

65,0

164,0

19

20172

8 x 2 x 0,75

blue

15,0

125,0

258,0

19

20173

10 x 2 x 0,75

blue

17,0

154,0

305,0

19

20174

12 x 2 x 0,75

blue

17,6

185,0

350,0

19

20175

16 x 2 x 0,75

blue

19,5

245,0

445,0

19

20176

20 x 2 x 0,75

blue

21,5

298,0

520,0

19

20177

24 x 2 x 0,75

blue

24,0

365,0

620,0

19

20178

36 x 2 x 0,75

blue

26,5

532,0

940,0

19

20179

48 x 2 x 0,75

blue

30,3

708,0

1250,0

19

20247

1 x 2 x 1,3

blue

8,7

31,0

102,0

-

20255

1 x 3 x 1,3

blue

9,0

44,0

116,0

-

20248

2 x 2 x 1,3

blue

11,5

62,0

161,0

-

20249

4 x 2 x 1,3

blue

14,3

114,0

230,0

-

20250

6 x 2 x 1,3

blue

15,8

168,0

310,0

-

20251

8 x 2 x 1,3

blue

17,3

218,0

377,0

-

20252

12 x 2 x 1,3

blue

20,5

322,0

515,0

-

20253

16 x 2 x 1,3

blue

23,0

426,0

656,0

-

20254

24 x 2 x 1,3

blue

27,9

684,0

952,0

-