RE-2Y(St)Yv

Instrumentation cable, reinforced outer sheath, meter marking

Logo Image
Produktfoto
Technical data
  • Computer cable in reference to
    EN 50288-79 (VDE 0819-7)
  • Conductor resistance  at 20°C
    0,5 mm²  max. 39,2 Ohm/km
    0,75 mm²  max. 24,6 Ohm/km
    1,3 mm²  max. 14,2 Ohm/km
  • Temperature range
    flexing  -5°C  to  +50°C
    fixed installation  -40°C  to  +70°C
  • Operating peak voltage max. 300 V
    (not for heavy current installation purposes)
  • Test voltage
    core/core  2000 V
    core/screen  1000 V
  • Mutual capacitance  at 800 Hz
    - core/core  0.5 mm²  approx. 60 pF/m
       for 1 and 2 pairs  approx. 75 pF/m
    - core/core  0.75 mm²  approx. 65 pF/m
       for 1 and 2 pairs  approx. 100 pF/m
    - core/core  1.3 mm²  approx. 75 pF/m
       for 1 and 2 pairs  approx. 100 pF/m
  • Inductance  max. 0,75 mH/km
  • Cross-talk attenuation
    at 60 kHz  min. 0,88 dB
  • Minimum bending radius
    fixed installation 7,5x outer Ø
Cable structure
  • Bare copper conductor, multi wire
  • Conductor construction:
    0,5 mm² = 7x0,3 mm
    0,75 mm² = 7x0,37 mm
    1,3 mm² = 7x0,49 mm
  • Core insulation of PE
  • Core identification
    coloured with numbering 1/1, 2/2 etc.
    pairs: BK, WH
    triads: BK, WH, RD
  • Cores twisted together in pairs / triads
    in optimal lay length
  • Pairs stranded in layer
  • 1 communication core 0,5 mm², PE-insulated,
    orange (for multicore version)
  • Foil wrapping
  • Electrostatic screen (St) made of plastic-
    laminated aluminium foil and tinned copper
    stranded drain wire, 0.5 mm² (7x0.3 mm)
  • Outer sheath of PVC, reinforced
  • Sheath colour: black (RAL 9005)
    or blue (RAL 5015)
  • With meter marking
Properties
  • Outdoor application
  • Low level of line attenuations and
    low mutual capacitances enable
    long transmission distances and
    fast pulse acceleration
  • The materials used during manufacturing
    are cadmium-free, contain no silicone
    and are free from substances harmful
    to the wetting properties of lacquers
Tests
  • Flame retardant acc. to 
    DIN VDE 0482-332-1-2 /
    DIN EN 60332-1-2 / IEC 60332-1-2
Note
  • Cop.weight including communication core
    and stranded drain wire
  • With blue outer sheath for hazardous areas
    to hazard type -i- for intrinsically safe
    installation acc. to DIN EN 60079-14
    section 16.2.2 (VDE 0165-1)
  • The conductor is metrically constructed
    (mm²). The AWG designation is
    approximate and purely informative.
Application
Instrumentation cables are used in data processing and process control. Low level of line attenuations and low mutual capacitances enable long transmission distances and fast pulse acceleration. Instrumentation cables are suitable for fixed installations in damp locations, in open spaces and for underground laying.
CE = Product conforms with Low-Voltage Directive 2014/35/EU.
Downloads
Data sheet
Certificate of compliance

Part no.

No.pairs x
cross-sec.
mm²

Sheath
colour

Outer Ø

app. mm

Cop.
weight

kg / km

Weight

app. kg / km

AWG-No.

20099

1 x 2 x 0,5

black

7,3

15,0

74,0

20

20100

2 x 2 x 0,5

black

9,3

30,0

117,0

20

20101

4 x 2 x 0,5

black

10,5

50,0

140,0

20

20233

6 x 2 x 0,5

black

12,2

70,0

190,0

20

20102

8 x 2 x 0,5

black

13,2

90,0

215,0

20

20103

10 x 2 x 0,5

black

14,7

110,0

220,0

20

20104

12 x 2 x 0,5

black

15,0

130,0

280,0

20

20105

16 x 2 x 0,5

black

16,8

170,0

352,0

20

20106

20 x 2 x 0,5

black

18,5

210,0

385,0

20

20107

24 x 2 x 0,5

black

19,9

250,0

468,0

20

20108