  • Special core insulation of PE
  • Conductor resistance
    0,5 mm²  max. 39,2 Ohm/km
    0,75 mm²  max. 24,6 Ohm/km
    1,3 mm²  max. 14,2 Ohm/km
  • Temperature range
    flexing -5°C  to  +50°C
    fixed installation -40°C  to  +70°C
  • Operating peak voltage max. 300 V
    (not for heavy current installation purposes)
  • Test voltage
    core/core  2000 V
    core/screen  1000 V
  • Mutual capacitance  at 800 Hz
    core/core  0.5 mm²  60 pF/m
    for 1 and 2 pairs  75 pF/m
    core/core  0.75 mm²  65 pF/m
    for 1 and 2 pairs  110 pF/m
    core/core  1.3 mm²  75 pF/m
    for 1 and 2 pairs  100 pF/m
  • Inductance
    max. 0,75 mH/km
  • Cross-talk attenuation
    at 60 kHz  min. 0,88 dB/km
  • Minimum bending radius
    7,5x outer Ø
Cable structure
  • Bare copper conductor, multi wire
  • Conductor construction:
    0,5 mm² = 7x0,3 mm
    0,75 mm² = 7x0,37 mm
    1,3 mm² = 7x0,49 mm
  • Core insulation of PE
  • Cores coloured
    with number print 1/1, 2/2 etc.
    pair: a-core = BK; b-core = WH
    triple: a-core = BK; b-core = WH;
    c-core = RD
  • Cores twisted to pairs with optimum pitch
  • Pairs stranded in layer
  • 1 communication core 0,5 mm², PE-insulated,
    orange (for multicore version)
  • Foil wrapping
  • Electrostatic screen (St) of plastics-coated
    metal foil
  • Tinned drain-wire, 0,5 mm² = 7x0,3 mm
  • Outer sheath of PVC, reinforced,
    black (RAL 9005) or blue (RAL 5015)
  • With meter marking
  • Wall-thickness acc. to
    DIN VDE 0816-1, table 7, col. 1
Properties
  • The electrostatic screen protect the
    screened pairs against outer electrostatic
    interference fields
  • Low level of line attenuations and low
    mutual capacitances enable long
    transmission distances and fast pulse
    acceleration
  • The materials used during manufacturing
    are cadmium-free, contain no silicone
    and are free from substances harmful
    to the wetting properties of lacquers
Tests
  • Self-extinguishing and flame retardant
    acc. to DIN VDE 0482-332-1-2 /
    DIN EN 60332-1-2 / IEC 60332-1-2
Note
  • Coppper weight including communication
    core and drain-wire.
  • With blue outer sheath for hazardous areas
    to hazard type -i- for intrinsically safe
    installation acc. to DIN EN 60079-14
    section 12.2.2 (VDE 0165-1)
  • The conductor is metrically constructed
    (mm²).  The AWG designation is
    approximate and purely informative.
Application
Instrumentation cables are used in data processing and process control. Instrumentation cables are suitable for fixed installations in damp locations, in open spaces and for underground laying.
CE = Product conforms with Low-Voltage Directive 2014/35/EU.
Downloads
Data sheet
Certificate of compliance

Part no.

No.pairs x
cross-sec.
mm²

Sheath
colour

Outer Ø

approx. mm

Cop.
weight

kg / km

Weight

approx. kg / km

AWG-No.

20099

1 x 2 x 0,5

black

7,5

15,0

74,0

20

20100

2 x 2 x 0,5

black

9,8

30,0

117,0

20

20101

4 x 2 x 0,5

black

11,3

50,0

140,0

20

20233

6 x 2 x 0,5

black

13,1

70,0

190,0

20

20102

8 x 2 x 0,5

black

14,6

90,0

215,0

20

20103

10 x 2 x 0,5

black

16,1

110,0

220,0

20

20104

12 x 2 x 0,5

black

16,4

130,0

280,0

20

20105

16 x 2 x 0,5

black

18,3

170,0

352,0

20

20106