MULTIFLEX 512®-C-PUR UL/CSA

special cable for drag chains, 80°C, 600 V, two approvals control cable, EMC-preferred type, halogen-free, meter marking

Logo Image Logo Image Logo Image
Produktfoto
Technical data
  • Special drag chain cables for extreme
    mechanical stress to UL Style 20939
  • Temperature range
    flexing -30°C to +80°C
    fixed installation -40°C to +80°C
  • Nominal voltage UL/CSA 600 V
  • Test voltage 3000 V
  • Insulation resistance
    min. 100 MOhm x km
  • Minimum bending radius
    flexing 7,5x cable Ø
    fixed installation 4x cable Ø
  • Alternating bending test
    tested with approx. 10 million
    bending cycles
  • Radiation resistance
    up to 50x106 cJ/kg (up to 50 Mrad)
  • Coupling resistance
    max. 250 Ohm/km
Cable structure
  • Bare copper, extra fine wire conductors,
    bunch stranded to DIN VDE 0295 cl.6,
    col. 4, BS 6360 cl.6 and IEC 60228 cl.6
  • Core insulation of special PP
  • Core identification to DIN VDE 0293
    black cores with continuous white
    numbering
  • GN-YE conductor, 3 cores and above
    in the outer layer
  • Cores stranded in layers with optimal
    selected lay length
  • Special core wrapping over each layers and
    an additional fleece over outer layer
  • TPE-inner sheath, halogen-free
  • Wrapping with special tapes
  • Tinned copper braided screening, approx.
    85% coverage
  • Special core wrapping of fleece (up to
    4 mm² without core wrapping over the outer
    layer)
  • Outer sheath of special full-polyurethane
    TMPU, to DIN VDE 0207-363-10-2 /
    DIN EN 50363-10-2
  • Sheath colour: grey (RAL 7001)
  • With meter marking
Properties
  • Very good oil resistant
  • Guaranteed permanent application in
    multi-shift operation under extreme high
    bending stress
  • Adhesion-low
  • High resistant to mechanical strain
  • High property of alternating bending
    strength
  • Long lifedurabilities through low
    fiction-resistance by using the TPE
    insulation
  • High tensile strength-, abrasion and
    impact resistant at low temperature
  • Resistant to Weather, Ozone, UV-radiation,
    Solvents, Acids and Alkalis, Hydraulic
    liquidity and Hydrolysis
  • The materials used during manufacturing
    are cadmium-free, contain no silicone
    and are free from substances harmful
    to the wetting properties of lacquers
Tests
  • PUR-sheath flame retardant acc. to
    DIN VDE 0482-332-1-2,
    DIN EN 60332-1-2 / IEC 60332-1
    (equivalent DIN VDE 0472 part 804
    test method B), UL VW-1, CSA FT1
Note
  • G = with green-yellow conductor
    x = without green-yellow conductor (OZ)
  • AWG sizes are approximate equivalent
    values. The actual cross section is in mm².
  • Please note the cleanroom qualification
    when ordering.
  • unscreened analogue type:
    MULTIFLEX 512® PUR UL/CSA
Application
The special screened UL/CSA cables for drag chains are mainly applied for impulse transmission to prevent external interference effects a