DATAFLAMM® -C

EMC-preferred type, halogen-free, screened, meter marking

Logo Image
Produktfoto
Technical data
  • Halogen-free special data cable
  • Temperature range
    flexing +5°C to +70°C
    fixed installation -40°C to +70°C
  • Operating peak voltage
    (not for heavy current installation purposes)
    0,14 mm² = 350 V
    ≥ 0,25 mm² = 500 V
  • Test voltage
    0,14 mm² = 800 V
    ≥ 0,25 mm² = 1200 V
  • Insulation resistance
    min. 2 GOhm x km
  • Capacitance
    core/core < 70 nF/km
  • Minimum bending radius
    flexing 7,5x cable Ø
    fixed installation 4x cable Ø
  • Coupling resistance
    max. 250 Ohm/km
  • Radiation resistance
    up to 100x106 cJ/kg (up to 100 Mrad)
Cable structure
  • Bare copper conductor, to
    DIN VDE 0812, fine wire
  • Conductor construction:
    0,34 mm² = 7x0,25 mm
  • Core insulation of PE
    compound type LD/MD to
    DIN VDE 0819-103 / DIN EN 50290-2-23
  • Core identification to DIN 47100
  • Cores stranded in layers with
    optimal lay length
  • Foil wrapping
  • Tinned copper braided screen,
    approx. 85% coverage
  • Outer sheath
    compound type HM2 to
    DIN VDE 0207 part 24
  • Sheath colour: grey (RAL 7005)
  • With meter marking
Properties
  • PE-insulated cores, compared with
    PVC-insulated cores, assure a remarkable
    and more favourable capacitance values
Tests
  • Halogen-free acc. to
    DIN VDE 0482-754-1,
    DIN EN 60754-1, IEC 60754-1
    (previously DIN VDE 0482-267-2-1)
  • Corrosiveness of combustion gases
    acc. to DIN VDE 0482-754-2,
    DIN EN 60754-2, IEC 60754-2
    (previously DIN VDE 0482-267-2-2)
  • Halogen-free sheath compound,
    self-extinguishing and flame retardant
    acc. to DIN VDE 0482-332-1-2,
    DIN EN 60332-1-2, IEC 60332-1-2
Note
  • AWG sizes are approximate equivalent
    values. The actual cross section is in mm².
  • Unscreened analogue type:
    DATAFLAMM®
Application
As a connecting and interconnecting cable for signaling, measuring, control and intercom purposes for the use in paging and intercom systems, clock systems, weighing equipment and office machines. The cables can be laid on or under plaster, in dry, damp and wet rooms as well as masonry and concrete. Areas of use are telecommunications and information processing systems in public buildings, laboratories, warehouses and other buildings in which the release of halogens in the event of fire must be avoided. Due to the screening without interference against foreign encoder or high-frequency signals.
EMC = Electromagnetic compatibility
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
CE = Product conforms with Low-Voltage Directive 2014/35/EU.
Downloads
Data sheet
Certificate of compliance

Part no.

No.cores x
cross-sec.
mm²

Outer Ø

approx. mm

Cop.
weight

kg / km

Weight

approx. kg / km

AWG-No.

52365

2 x 0,14

3,7

12,4

21,0

26

52366

3 x 0,14

3,9

14,0

25,0

26

52367

4 x 0,14

4,1

15,8

26,0

26

52368

5 x 0,14

4,4

19,5

32,0

26

52369

7 x 0,14

4,7

23,4

39,0

26